Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 9(1): 1620, 2019 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-30733586

RESUMEN

Because of its ideal band gap, high density and high electron mobility-lifetime product, cadmium zinc telluride (CdZnTe or CZT) is currently the best room-temperature compound-semiconductor X- and gamma-ray detector material. However, because of its innate poor thermo-physical properties and above unity segregation coefficient for Zn, the wide spread deployment of this material in large-volume CZT detectors is still limited by the high production cost. The underlying reason for the low yield of high-quality material is that CZT suffers from three major detrimental defects: compositional inhomogeneity, high concentrations of dislocation walls/sub-grain boundary networks and high concentrations of Te inclusions/precipitates. To mitigate all these disadvantages, we report for the first time the effects of the addition of selenium to the CZT matrix. The addition of Se was found to be very effective in arresting the formation of sub-grain boundaries and its networks, significantly reducing Zn segregation, improving compositional homogeneity and resulting in much lower concentrations of Te inclusions/precipitates. Growth of the new quaternary crystal Cd1-xZnxTe1-ySey (CZTS) by the Traveling Heater Method (THM) is reported in this paper. We have demonstrated the production of much higher yield according to its compositional homogeneity, with substantially lower sub-grain boundaries and their network, and a lower concentration of Te inclusions/precipitates.

2.
Sci Rep ; 6: 26384, 2016 05 24.
Artículo en Inglés | MEDLINE | ID: mdl-27216387

RESUMEN

CdZnTe (CZT) has made a significant impact as a material for room-temperature nuclear-radiation detectors due to its potential impact in applications related to nonproliferation, homeland security, medical imaging, and gamma-ray telescopes. In all such applications, common metals, such as gold, platinum and indium, have been used as electrodes for fabricating the detectors. Because of the large mismatch in the thermal-expansion coefficient between the metal contacts and CZT, the contacts can undergo stress and mechanical degradation, which is the main cause for device instability over the long term. Here, we report for the first time on our use of Al-doped ZnO as the preferred electrode for such detectors. The material was selected because of its better contact properties compared to those of the metals commonly used today. Comparisons were conducted for the detector properties using different contacts, and improvements in the performances of ZnO:Al-coated detectors are described in this paper. These studies show that Al:ZnO contacts to CZT radiation detectors offer the potential of becoming a transformative replacement for the common metallic contacts due to the dramatic improvements in the performance of detectors and improved long-term stability.

3.
IEEE Trans Nucl Sci ; 63(1): 316-324, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27182081

RESUMEN

Baseline holder (BLH) circuits are used widely to stabilize the analog output of application-specific integrated circuits (ASICs) for high-count-rate applications. The careful design of BLH circuits is vital to the overall stability of the analog-signal-processing chain in ASICs. Recently, we observed self-triggered fluctuations in an ASIC in which the shaping circuits have a BLH circuit in the feedback loop. In fact, further investigations showed that methods of enhancing small-signal stabilities cause an even worse situation. To resolve this problem, we used large-signal analyses to study the circuit's stability. We found that a relatively small gain for the error amplifier and a small current in the non-linear stage of the BLH are required to enhance stability in large-signal analysis, which will compromise the properties of the BLH. These findings were verified by SPICE simulations. In this paper, we present our detailed analysis of the BLH circuits, and propose an improved version of them that have only minimal self-triggered fluctuations. We summarize the design considerations both for the stability and the properties of the BLH circuits.

4.
Rev Sci Instrum ; 86(7): 073114, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26233363

RESUMEN

We developed a robust and low-cost array of virtual Frisch-grid CdZnTe detectors coupled to a front-end readout application-specific integrated circuit (ASIC) for spectroscopy and imaging of gamma rays. The array operates as a self-reliant detector module. It is comprised of 36 close-packed 6 × 6 × 15 mm(3) detectors grouped into 3 × 3 sub-arrays of 2 × 2 detectors with the common cathodes. The front-end analog ASIC accommodates up to 36 anode and 9 cathode inputs. Several detector modules can be integrated into a single- or multi-layer unit operating as a Compton or a coded-aperture camera. We present the results from testing two fully assembled modules and readout electronics. The further enhancement of the arrays' performance and reduction of their cost are possible by using position-sensitive virtual Frisch-grid detectors, which allow for accurate corrections of the response of material non-uniformities caused by crystal defects.

5.
Artículo en Inglés | MEDLINE | ID: mdl-28626357

RESUMEN

A new low-power application-specific integrated circuit (ASIC) for Cadmium Zinc Telluride (CZT) detectors for single-photon emission computed tomography (SPECT) application is being developed at BNL. As the first step, a 32-channel prototype ASIC was designed and tested recently. Each channel has a preamplifier followed by CR-RC3 shaping circuits and three independent energy bins with comparators and 16-bit counters. The ASIC was fabricated with TSMC 0.35-µm complementary metal-oxide-semiconductor (CMOS) process and tested in laboratories. The power consumption is around 1 mW/ch with a 2.5-V supply. With a gain of 400 mV/fC and the peaking time of 500 ns, the equivalent noise charge (ENC) of 360 e- has been measured in room temperature while the crosstalk rate is less than 0.3%. The 10-bit DACs for global thresholds have an integral nonlinearity (INL) less than 0.56% and differential nonlinearity (DNL) less than 0.33%. In the presentation, we will report the detailed test results with this ASIC.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...